Analytical formulation for the shielding effectiveness of enclosures with apertures

Research output: Contribution to journalArticle

Full text download(s)

Published copy (DOI)

Author(s)

Department/unit(s)

Publication details

JournalIEEE Transactions on Electromagnetic Compatibility
DatePublished - 1 Aug 1998
Issue number3
Volume40
Number of pages9
Pages (from-to)240-248
Original languageEnglish

Abstract

An analytical formulation has been developed for the shielding effectiveness of a rectangular enclosure with an aperture. Both the magnetic and electric shielding may be calculated as a function of frequency, enclosure dimensions, aperture dimensions and position within the enclosure. Theoretical values of shielding effectiveness are in good agreement with measurements. The theory has been extended to account for circular apertures, multiple apertures, and the effect of the enclosure contents.

The captions for Figures 12-16 were incorrect in the original published version. The captions should be:
12. Emissions measurement of shielding at centre of 300x120x300 mm enclosure with 150x40 mm aperture compared to calculated SE and SM.
13. Effect of loss term zeta on calculated SE.
14. Measured SE with various sized blocks of RAM in enclosure.
15. Measured SE with two different circuit boards in enclosure.
16. Measured and calculated SE at centre of 300 x 120 x 300mm enclosure with 88mm diameter circular aperture.

    Research areas

  • apertures, circuit modeling, electromagnetic compatibility, electrical equipment enclosures, electromagnetic shielding