Applying IEC 62132-2 to the real world: Immunity of an analogue to digital converter

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The susceptibility of an analogue to digital (A/D) converter was measured according to IEC 62132-2 (TEM cell). The chip on its own had a high immunity as the lead-frame presents a small loop area and picks up little energy from an interfering source. With a small (15mm) track added the immunity was greatly reduced and showed a number that the interference had least effect at harmonics of the A/D converter clock frequency.

Original languageEnglish
Title of host publication2008 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE)
Place of PublicationHamburg, Germany
Pages477-480
Number of pages4
ISBN (Electronic)978-3-930400-60-7
DOIs
Publication statusPublished - 8 Aug 2008