Measurements and Power Balance Modelling of the Shielding Effectiveness of Partitioned Equipment Enclosures

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

This paper presents calculated and measured Shielding Effectiveness data for shielded enclosures operated in the frequency range where the enclosure is reverberant. The calculated data are obtained from component measurements and are calculated using the Power Balance technique. The Shielding Effectiveness of the different cavities of an enclosure partitioned by stacked circuit cards is obtained.
Original languageEnglish
Title of host publication2019 International Symposium on Electromagnetic Compatibility - EMC EUROPE
Pages158-162
Number of pages5
Publication statusPublished - 2 Sept 2019

Publication series

NameEMC Europe

Bibliographical note

Accepted 11 April 2019

Keywords

  • shielding effectiveness of enclosures
  • power balance method
  • reverberant environment